Showing posts with label mobile. Show all posts
Showing posts with label mobile. Show all posts

Thursday, August 8, 2013

A Friendly Charger Circuit for Mobile Phones

Most mobile chargers do not have current/voltage regulation or short-circuit protection. These chargers provide raw 6-12V DC for charging the battery pack. Most of the mobile phone battery packs have a rating of 3.6V, 650mAh. For increasing the life of the battery, slow charging at low current is advisable. Six to ten hours of charging at 150-200mA current is a suitable option. This will prevent heating up of the battery and extend its life.

Circuit diagram:

A Friendly Charger Circuit  For Mobile Phones A Friendly Charger Circuit Diagram For Mobile Phones

Parts:

Resistors:
P1 = 10K LOG
R1 = 1K
R2 = 1K
R3 = 1K
R4 = 1K
R5 = 3.3K
R6 = 16R/2W
R7 = 220R
R8 = 3.3R
R9 = 1K

Capacitors:

C1 = 470uF/25V
C2 = 10uF/25V
C3 = 1KuF/25V

Semiconductors:

D1 = Red LED
D2 = Green LED
Q1 = BC547
Q2 = BD677
ZD1 = 12V/1W
ZD2 = 5.6V/1W
IC1 = CA3130

Description:

The circuit described here, provides around 180mA current at 5.6V and protects the mobile phone from unexpected voltage fluctuations that develop on the mains line. So the charger can be left ‘on’ over night to replenish the battery charge. The circuit protects the mobile phone as well as the charger by immediately disconnecting the output when it senses a voltage surge or a short circuit in the battery pack or connector. It can be called a ‘middle man’ between the existing charger and the mobile phone.

It has features like voltage and current regulation, over-current protection, and high- and low-voltage cut-off. An added specialty of the circuit is that it incorporates a short delay of ten seconds to switch on when mains resumes following a power failure. This protects the mobile phone from instant voltage spikes. When short-circuit occurs at the battery terminal, resistor R8 senses the over-current, allowing Q1 to conduct and light up D1. Glowing of D2 indicates the charging mode, while D1 indicates short-circuit or over-current status.

The value of resistor R8 is important to get the desired current level to operate the cut-off. With the given value of R8 (3.3 ohms), it is 350 mA. Charging current can also be changed by increasing or decreasing the value of R7 using the ‘I=V/R’ rule. Construct the circuit on a common PCB and house in a small plastic case. Connect the circuit between the output lines of the charger and the input pins of the mobile phone with correct polarity.

Author : D. Mohan Kumar Copyright : E F Y


Read the rest entry[...]

Friday, April 12, 2013

Mobile Incoming Call Indicator Circuit Diagram

This circuit can be used to escape from the nuisance of mobile phone rings
when you are at home. This circuit will give a visual indication if
placed near a mobile phone even if the ringer is deactivated.


When
a call is coming to the mobile phone, the transmitter inside it becomes
activated. The  frequency of the transmitter is around 900MHz.The 
coil L1 picks up these oscillations by induction and feds it to the
base of Q1. This makes the transistor Q1 activated.Since the Collector
of Q1 is connected to the pin 2 of IC1 (NE555) , the IC1 is triggered to make the LED connected at  its output pin (pin 3) to blink. The blinking of the LED is the indication of incoming call.
Notes:
  •   
    The coil L1 can be made by making 150 turns of 36 SWG enameled copper
    wire on a 5mm dia   plastic former.Or you can purchase a 10 uH coil from
    shop if available.
  •     The circuit can be powered from a 6V battery.
  •     Assemble the circuit on a good quality PCB.
  •     C1 & C3 are to be polyester  capacitors.
  •     The electrolytic capacitor C2 must be rated 10V.