This current can be used directly, or it can be converted into a voltage by means of a load resistor RL. In the latter case, the ‘floating’ measurement voltage across the shunt is converted into a voltage with respect to earth, which is easy to use. The value of RL determines the gain. A value of 5 kΩ gives 1×, 10 kΩ gives 2×, 15 kΩ gives 3× and so on. It all works as follows. Just like any opamp, this IC tries to maintain the same potential on its internal plus and minus inputs. The minus input is connected to the left-hand end of the shunt resistor via a 5-kΩ resistor.

The INA138 can handle voltages between 2.7 and 36 V, while the INA168 can work up to 60 V. The supply voltage on pin 5 may lie anywhere between these limits, regardless of the voltage on the inputs. This means that even with a supply voltage of only 5 V, you can make measurements with up to 60 V on the inputs! However, in most cases it is simplest to connect pin 5 directly to the voltage on pin 3. Bear in mind that the value of the supply voltage determines the maximum value of the output voltage. Also, don’t forget the internal base-emitter junction voltage of T1 (0.7 V), and the voltage drop across the shunt also has to be subtracted.